View Issue Details

IDProjectCategoryView StatusLast Update
0002318Industrial-Craft²machinespublic2020-08-06 19:13
Reporterb2soft Assigned ToChocohead  
PriorityhighSeveritymajorReproducibilityalways
Status closedResolutionno change required 
Fixed in VersionBuilds for MC 1.10.x 
Summary0002318: Steam Boiler produces steam explosions instead of normal work
DescriptionIn MC 1.10.2 with Ic2 build 254 when I'm trying to use Steam Boiler + Steam Turbines I get this: https://1drv.ms/v/s!AutddSeez-MhgYVYWHoli3mXlqcWqQ
Explosions are surrounded by the explosion sound. Steam boiler is set up to 221 mbars/ 1 mB/tick. Turbines also work 1 tick, idle 1 tick, work 1 tick, idle 1 tick (as shown by turbines' animations on video).

When Boiler is not heated enough, there is no message of which will be produced as an output.
Steps To Reproduce1. Place machines as on the video.
2. Place Distilled water / Water to Steam Boiler.
3. Set 221 mBar as Output pressure and 1 mB/tick as Input flow.
4. Enable heater to heat up Boiler.
5. The bug happens at 0000124:0000350 C.
6. See unstable output from Kinetic Generator
Tags1.10.2, steam
Minecraft Version1.10.2

Activities

b2soft

2018-02-07 17:23

reporter   ~0005542

Correction: Step 5. The bug happens at 350 at degrees of temperature

Chocohead

2018-02-07 18:17

developer   ~0005543

You don't have a condenser touching the top turbine, it's probably stuck full of distilled water and it's trying to push it back into the boiler every other tick.

b2soft

2018-02-07 18:18

reporter   ~0005544

Yes, it has some distilled water, but much less than 10% (like 10-20 mB)

b2soft

2018-02-07 19:51

reporter   ~0005545

Added video with condenser
https://1drv.ms/v/s!AutddSeez-MhgYVZk0rjsXF2a__MEw

Chocohead

2018-02-07 20:16

developer   ~0005546

Last edited: 2018-02-07 20:17

Ah no I see what's happening now, you're only supplying 100HU/t but it needs 200HU/t to run constantly. Thus you're getting a tick of production then the next tick has to buffer heat before it can output. And because you've got perfectly half the needed heat, it will flip every tick exactly.

Issue History

Date Modified Username Field Change
2018-02-07 17:19 b2soft New Issue
2018-02-07 17:19 b2soft Tag Attached: 1.10.2
2018-02-07 17:19 b2soft Tag Attached: steam
2018-02-07 17:23 b2soft Note Added: 0005542
2018-02-07 18:17 Chocohead Note Added: 0005543
2018-02-07 18:18 b2soft Note Added: 0005544
2018-02-07 19:51 b2soft Note Added: 0005545
2018-02-07 20:16 Chocohead Note Added: 0005546
2018-02-07 20:17 Chocohead Note Edited: 0005546
2018-02-10 14:43 Chocohead Assigned To => Chocohead
2018-02-10 14:43 Chocohead Status new => resolved
2018-02-10 14:43 Chocohead Resolution open => no change required
2018-02-10 14:43 Chocohead Fixed in Version => Builds for MC 1.10.x
2020-08-06 19:13 b2soft Status resolved => closed