Summary | 0002304: Stirling-Cheating Generator | ||||
Description | Set up Stirling generator to Electric Heater(with coils), Liquid Heat Exchanger(with Heat Conductors) or Solid Fuel Firebox(empty) stirling start generating energy without actually heat. Liquid Fuel Firebox and Radioisotope Heat Generator not have this issue. Other heat mechanical machines settings work fine. | ||||
Steps To Reproduce | 1 Put Stirling generator next to Liquid Heat Exchanger with heat connections are touching each other. 2 Liquid Heat Exchanger need Heat Conductors minimum 1. 3 Stirling generator generate EU/t according to NOT EXISTING HU/t. | ||||
Additional Information | list of my mods: buildcraft-7.99.14.jar CodeChickenLib-1.12.2-3.1.5.331-universal.jar CoFHCore-1.12.2-4.3.10.5-universal.jar CoFHWorld-1.12.2-1.1.1.12-universal.jar hud-1.3.9-1.12.jar Hwyla-1.8.23-B38_1.12.jar industrialcraft-2-2.8.42-ex112.jar jei_1.12.2-4.8.5.144.jar journeymap-1.12.2-5.5.2.jar JustEnoughResources-1.12.2-0.8.6.28.jar KeepingInventory-1.12.2-2.4.jar RedstoneFlux-1.12-2.0.1.2-universal.jar Scannable-MC1.12-1.6.2.13.jar ThermalDynamics-1.12.2-2.3.10.4-universal.jar ThermalExpansion-1.12.2-5.3.10.14-universal.jar TreeChopper-1.12.2-1.2.4.jar Wawla-1.12.2-2.5.246.jar | ||||
Tags | No tags attached. | ||||
Minecraft Version | 1.12.2 | ||||
|
That doesn't sound good... Definitely needs fixing |
|
Fixed in IC2 2.8.43. Please do report back if the Kinetic Generator or Stirling Generator are less reliable, especially on chunk borders and world loads. They shouldn't be, but there is the potential for them to be because of the fixes. |
|
So far everything works fine. |
|
Good to hear |
|
@Chocohead Could this have something to do with the "Stirling Kinetic Generator", or does your comment only apply to the "Stirling" and "Kinetic" generators? We are having trouble in our server where the stirling kinetic generators that we built as a large energy tower stop working after a while. Removing and replacing the stirling kinetic generators makes them work again for a while, but if left alone, they will not work even when receiving heat. If this is not related to the above issue please let me know and I'll submit a separate bug report. I just thought this might be related so I asked here first. Thanks! |
|
That was only about just the Stirling Generator and the Kinetic Generator, as they both share the same logic just for different interfaces. The Stirling Kinetic Generator is completely separate so unless you've got it going into a kinetic generator, any problems with it are unrelated. |
Date Modified | Username | Field | Change |
---|---|---|---|
2018-01-21 07:03 | Scaran | New Issue | |
2018-01-21 17:10 | Chocohead | Note Added: 0005511 | |
2018-01-24 14:50 | Chocohead | Assigned To | => Chocohead |
2018-01-24 14:50 | Chocohead | Status | new => resolved |
2018-01-24 14:50 | Chocohead | Resolution | open => fixed |
2018-01-24 14:50 | Chocohead | Fixed in Version | => Builds for MC 1.12.x |
2018-01-24 14:50 | Chocohead | Note Added: 0005514 | |
2018-01-24 17:38 | Scaran | Note Added: 0005515 | |
2018-01-24 18:32 | Chocohead | Note Added: 0005516 | |
2018-01-25 12:12 | Chocohead | Relationship added | parent of 0002307 |
2018-07-01 12:50 | setzer22 | Note Added: 0005728 | |
2018-07-01 19:32 | Chocohead | Note Added: 0005729 |