View Issue Details
| ID | Project | Category | View Status | Date Submitted | Last Update | 
|---|---|---|---|---|---|
| 0002679 | Industrial-Craft² | E-Net, cabling, storage/transformer blocks | public | 2020-04-16 20:25 | 2020-05-27 13:24 | 
| Reporter | Su5eD | Assigned To | estebes | ||
| Priority | immediate | Severity | major | Reproducibility | always | 
| Status | acknowledged | Resolution | open | ||
| Summary | 0002679: Machine doesn't explode if re-connected to higher voltage | ||||
| Description | The machine doesn't explode if you first connect it to it's normal tier, and then re-connect it to a higher tier it shouldn't be able to run on. It can still operate. IC2 build: 2.8.197 | ||||
| Steps To Reproduce | 1.Get a machine (for example a compressor) 2.Connect it to itps normal voltage (32 EU/t) 3.Disconnect cable 4.Connect it to high voltage 5.It doesn't explode | ||||
| Additional Information | Video showing bug: https://imgur.com/Mb5FWft | ||||
| Tags | 1.12.2, 1.12.2-2-2.8.197-ex112, cable, EU, Urgent, Voltage | ||||
| Minecraft Version | 1.12.2 | ||||
| Date Modified | Username | Field | Change | 
|---|---|---|---|
| 2020-04-16 20:25 | Su5eD | New Issue | |
| 2020-04-16 20:25 | Su5eD | Tag Attached: 1.12.2 | |
| 2020-04-16 20:25 | Su5eD | Tag Attached: 1.12.2-2-2.8.197-ex112 | |
| 2020-04-16 20:25 | Su5eD | Tag Attached: cable | |
| 2020-04-16 20:25 | Su5eD | Tag Attached: EU | |
| 2020-04-16 20:25 | Su5eD | Tag Attached: Urgent | |
| 2020-04-16 20:25 | Su5eD | Tag Attached: Voltage | |
| 2020-05-03 13:11 | Su5eD | Note Added: 0006225 | |
| 2020-05-27 13:24 | estebes | Relationship added | related to 0002665 | 
| 2020-05-27 13:24 | estebes | Assigned To | => estebes | 
| 2020-05-27 13:24 | estebes | Status | new => acknowledged | 