View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0001391 | Industrial-Craft² | E-Net, cabling, storage/transformer blocks | public | 2014-09-10 15:54 | 2015-06-28 14:46 |
Reporter | matix931 | Assigned To | Aroma1997 | ||
Priority | normal | Severity | minor | Reproducibility | always |
Status | resolved | Resolution | fixed | ||
Product Version | Builds for MC 1.7.10 | ||||
Fixed in Version | Builds for MC 1.7.10 | ||||
Summary | 0001391: HV transformer is not lowering EU/t | ||||
Description | Output and input eu/t from hv transformer is the same - 2048 eu/t. Force refresh is not working, only blinks for a moment 512 eu/t on output, but it return to 2048 eu/t. IC2 .640 Forge .1208 | ||||
Additional Information | Screen shot as attachment. | ||||
Tags | No tags attached. | ||||
Minecraft Version | |||||
Date Modified | Username | Field | Change |
---|---|---|---|
2014-09-10 15:54 | matix931 | New Issue | |
2014-09-10 15:54 | matix931 | File Added: ss.png | |
2014-09-10 16:17 | matix931 | File Added: SWKu7Be.png | |
2014-09-10 16:18 | matix931 | Note Added: 0003434 | |
2014-09-11 17:45 | Thunderdark | Assigned To | => Player |
2014-09-11 17:45 | Thunderdark | Status | new => assigned |
2015-06-28 14:46 | Aroma1997 | Status | assigned => resolved |
2015-06-28 14:46 | Aroma1997 | Fixed in Version | => Builds for MC 1.7.10 |
2015-06-28 14:46 | Aroma1997 | Resolution | open => fixed |
2015-06-28 14:46 | Aroma1997 | Assigned To | Player => Aroma1997 |