View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0002515 | Industrial-Craft² | E-Net, cabling, storage/transformer blocks | public | 2019-03-19 14:28 | 2019-03-20 01:44 |
Reporter | KrisBigK | Assigned To | |||
Priority | high | Severity | major | Reproducibility | always |
Status | new | Resolution | open | ||
Platform | PC, Java | OS | Windows | OS Version | 7 |
Summary | 0002515: Splitter cable still stops the whole E-net | ||||
Description | After powering the splitter cable that has 2 cables connected to it, the whole E-net shuts down. De-powering the cable or breaking and replacing the cable re-activates the E-net again. Also, re-entering the game can fix it. | ||||
Steps To Reproduce | 1.Set up the structure in the screenshot. The MFSU on the left can emit EU while the right ones can accept EU. Don't power the splitter cable. 2.Observe that EU is flowing normally from the left to the right 3.Power the splitter cable 4.Observe EU has stopped flowing 5.De-power the splitter cable 6.Observe that everything is normal again. | ||||
Additional Information | Mod list DebugServerInfo-1.12.2-1.0.5 industrialcraft-2-2.8.111-ex112 jei_1.12.2-4.13.1.225 LagGoggles-FORGE-1.12.2-4.1 TickrateChanger-Mod-1.12.2 torohealth-1.12-11 | ||||
Tags | No tags attached. | ||||
Minecraft Version | 1.12.2 | ||||
duplicate of | 0002287 | new | EU stop flowing when destroying one side of a split cable |