View Issue Details

IDProjectCategoryView StatusLast Update
0000403Industrial-Craft²E-Net, cabling, storage/transformer blockspublic2013-05-21 21:37
ReporterAlexKass Assigned ToPlayer  
PrioritynormalSeverityminorReproducibilityalways
Status closedResolutionno change required 
PlatformPCOSWindowsOS Version7 x64
Summary0000403: Power cut in Tin cable-Solar panel setup
DescriptionOn screenshot is seen setup of solar panels connected by tin cable (MFS is below roof). Maximum EU/t gain from this setup is 7. Adding more solar panels gives no effect.
If left part is cut off, max power is 4.
So I guess, that the power loss of Tin cable is not 0.025 per block, but 0.25.
Steps To ReproduceOnly under open sky:
1. Build BatBox/MFU/MFS unit.
2. Make Tin Cable, length over 7, connected to device.
3. Make chain of solar panels.
4. Measure energy output.
TagsNo tags attached.
Minecraft Version

Activities

AlexKass

2013-05-19 15:44

reporter  

2013-05-19_19.32.25.png (433,535 bytes)

Player

2013-05-20 13:21

administrator  

2013-05-20_15.21.03.png (675,036 bytes)

Player

2013-05-20 13:21

administrator   ~0000993

works for me, see screenshot?

AlexKass

2013-05-21 07:31

reporter   ~0000999

Found mistake in my setup, had HV cable in this chain. Sorry for bothering. Everything working correctly.

Issue History

Date Modified Username Field Change
2013-05-19 15:44 AlexKass New Issue
2013-05-19 15:44 AlexKass File Added: 2013-05-19_19.32.25.png
2013-05-20 13:21 Player File Added: 2013-05-20_15.21.03.png
2013-05-20 13:21 Player Note Added: 0000993
2013-05-20 13:21 Player Assigned To => Player
2013-05-20 13:21 Player Status new => feedback
2013-05-21 07:31 AlexKass Note Added: 0000999
2013-05-21 07:31 AlexKass Status feedback => assigned
2013-05-21 21:37 Player Status assigned => closed
2013-05-21 21:37 Player Resolution open => no change required