View Issue Details

IDProjectCategoryView StatusLast Update
0001936Industrial-Craft²machinespublic2016-08-13 15:38
Reporterlach_01298 Assigned ToAroma1997  
PriorityhighSeveritymajorReproducibilityalways
Status closedResolutionno change required 
OSwindows 10 
Summary0001936: wind turbine blowing up LV and MV machines
DescriptionWhen an active wind turbine is connected to a low voltage machine (batbox) or medium voltage machine (CESU) the machine explodes even though the out put of the kinetic generator is lower than 32 EU/t
Steps To Reproducesetup wind turbine going into a kinetic generator. put the rotor in turbine. connect a LV or MV machine to the generator. works every time.
TagsNo tags attached.
Minecraft Version1.10.2

Relationships

has duplicate 0001949 closedChocohead Kinetic wind generator explodes non-HV equipment, even when producing less than 128 EU/t (2.6.24) 

Activities

Aroma1997

2016-07-22 17:43

developer   ~0004636

This is not a bug. In the tooltip, it clearly says, the generator has a power tier of 3 (HV). The kinetic generator has an internal buffer, that can fill up and then release large amounts of energy at once.

Issue History

Date Modified Username Field Change
2016-07-22 08:15 lach_01298 New Issue
2016-07-22 17:43 Aroma1997 Note Added: 0004636
2016-07-22 17:43 Aroma1997 Status new => closed
2016-07-22 17:43 Aroma1997 Assigned To => Aroma1997
2016-07-22 17:43 Aroma1997 Resolution open => no change required
2016-08-13 15:38 Chocohead Relationship added has duplicate 0001949