View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0002506 | Industrial-Craft² | E-Net, cabling, storage/transformer blocks | public | 2019-03-10 11:16 | 2019-08-04 22:49 |
Reporter | KrisBigK | Assigned To | |||
Priority | low | Severity | minor | Reproducibility | random |
Status | new | Resolution | open | ||
Platform | PC, Java | OS | Windows | OS Version | 7 |
Summary | 0002506: Splitter cable sometimes don't update | ||||
Description | In my save file, the splitter cable at x=2,y=34,z=10 sometimes don't update when the reactor is turned off. This happened at least twice before where there is no EU flowing through it by checking the MFSU, but the EU reader said it has 150 EU/t input. | ||||
Steps To Reproduce | 1.turn on the reactor main switch lever 2.wait for a few minutes 3.turn it off 4.check the splitter cable after the boilers have stopped generating steam | ||||
Additional Information | Mod list DebugServerInfo-1.12.2-1.0.5 industrialcraft-2-2.8.111-ex112 jei_1.12.2-4.13.1.225 TickrateChanger-Mod-1.12.2 torohealth-1.12-11 | ||||
Tags | No tags attached. | ||||
Minecraft Version | 1.12.2 | ||||
related to | 0002287 | new | EU stop flowing when destroying one side of a split cable |
|
I forgot to mention that breaking the fiber glass cable next to the splitter cable and re-placing that cable fixes it. |
|
I found out that all "splitter cable" mentioned above should be detector cable. I always mix them up. I apologize for that. |
|
I just managed to re-produce this bug again a few times in a row. Steps to reproduce: 1.Go to the reactor at roughly 0,0 if spawned somewhere else 2.If the reactor is running normally (if it's on a 2 sec on and 5 sec off cycle and if its core temperature is always above 50%), skip step 3. 3.Flick the lever at 10 29 22 to turn it off, wait for a few secs and turn it on. Wait until the reactor is running normally again. (It takes about 30s) 4.Punch any one of the slime block at 3 34 6, 3 30 6, 6 32 2, which simulates a boiler explosion. 5.After about a second you should hear sound from note blocks and the reactor shuts off 6.If 5 happens then go to 0 35 10. The detector cable is on the east side at 2 35 10 7.Open the MFSU GUI and wait until EU stops flowing in 8.Observe the detector cable, EU-reader says there is a current, but actually there isn't To reset everything, place the slime block back where it was and press the button at 14 29 13. The reactor should run normally again. |
Date Modified | Username | Field | Change |
---|---|---|---|
2019-03-10 11:16 | KrisBigK | New Issue | |
2019-03-10 11:18 | KrisBigK | File Added: automated fluid reactor - 1.zip | |
2019-03-10 11:18 | KrisBigK | Note Added: 0005947 | |
2019-03-11 10:07 | KrisBigK | Note Added: 0005948 | |
2019-07-02 02:11 | KrisBigK | File Added: automated fluid reactor - 1 - working2.zip | |
2019-07-02 02:11 | KrisBigK | Note Added: 0006049 | |
2019-08-04 22:49 | Chocohead | Relationship added | related to 0002287 |